INAPPROPRIATE OPERATION AND CONTROL RECORD 0x43 (UNUSUAL VOLTAGE OF A BATTERY OR CAPACITOR) [PCM (SKYACTIV-G 2.5T)]
id0102s8043200
Outline
Operation Conditions
Protection Control
Diagnosis Procedure and Explanation to Customer
STEP |
INSPECTION |
RESULTS |
ACTION |
---|---|---|---|
1
|
PURPOSE: VERIFY DTCs
• Has any DTC been recorded?
|
Yes
|
Repair the malfunctioning location according to the applicable DTC troubleshooting.
|
No
|
Go to the next step.
|
||
2
|
PURPOSE: VERIFY CONDITION OF BATTERY, GENERATOR, CAPACITOR (i-ELOOP), AND DC-DC CONVERTER (i-ELOOP)
• Inspect the battery, generator, capacitor (i-ELOOP), and DC-DC converter (i-ELOOP) referring to the troubleshooting procedure for DTC P2504:00.
• Is there any malfunctioning location?
|
Yes
|
Repair the malfunctioning location.
|
No
|
Explain to the customer that the vehicle is normal and the protection control was performed temporarily due to signal noise.
|