AUTO HOLD SWITCH INSPECTION [WITH AUTO HOLD]
id0415008028f3
Continuity Inspection
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the electric parking brake switch. (See ELECTRIC PARKING BRAKE SWITCH REMOVAL/INSTALLATION.)
3. Verify that the continuity is as indicated in the table.
|
|
Illumination Light Inspection
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the electric parking brake switch. (See ELECTRIC PARKING BRAKE SWITCH REMOVAL/INSTALLATION.)
3. Apply battery positive voltage to electric parking brake switch terminal I, and connect terminal J to ground.
|
4. Verify that the illumination light turns on.
|
Indicator Light Inspection
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the electric parking brake switch. (See ELECTRIC PARKING BRAKE SWITCH REMOVAL/INSTALLATION.)
3. Apply battery positive voltage to electric parking brake switch terminal K, and connect terminal B to ground.
|
4. Verify that the indicator light turns on.
|