PID/DATA MONITOR TABLE [POWER LIFTGATE (PLG) CONTROL MODULE]
id0902o8960700
PID |
Unit/Operation |
Data contents |
Module control terminal |
---|---|---|---|
BG_ST
|
DEAD/INITIAL/PRE ARMING/ARMING/ARMING SB/ALARM/ALARM SB
|
• DEAD: Ignition is in ACC or ON (engine off) and alarm cannot be activated.
• INITIAL: Ignition is switched OFF and transition to arming stand-by status is possible.
• PRE ARMING: Transition period to arming status.
• ARMING: Alarm can be activated by inputting alarm trigger.
• ARMING SB: Liftgate is open under arming status.
• ALARM: Alarm trigger is input and alarm is activated.
• ALARM SB: After alarm activation finished, standing by for next alarm trigger input.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
CLM_CL_CV
|
Off/On
|
• Off: Liftgate lock actuator close is not operating.
• On: Liftgate lock actuator close is operating.
|
• 2G (Closure motor (Open))
• 2J (Closure motor (Closed))
|
CLM_CL_V
|
V
|
Displays the voltage during a close operation of the liftgate lock actuator.
|
—
|
CLM_CUR
|
A
|
Displays the current during liftgate lock actuator operation.
|
• 2G (Closure motor (Open))
• 2J (Closure motor (Closed))
|
CLM_OP_CV
|
Off/On
|
• Off: Liftgate lock actuator open is not operating.
• On: Liftgate lock actuator open is operating.
|
• 2G (Closure motor (Open))
• 2J (Closure motor (Closed))
|
CLM_OP_V
|
V
|
Displays the voltage during a open operation of the liftgate lock actuator.
|
—
|
CTS_SW
|
Off/On
|
• Off: Liftgate is closed. (Liftgate latch switch is off.)
• On: Liftgate is open. (Liftgate latch switch is on.)
|
1S (Liftgate condition)
|
DL_ST
|
Lock/Unlock
|
• Lock: Door/liftgate is locked.
• Unlock: Door/liftgate is unlocked.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
FL_SW
|
Off/On
|
• Off: Full latch switch is off.
• On: Full latch switch is on.
|
1O (Full latch switch)
|
GT_SW
|
Off/On
|
• Off: Power liftgate (PLG) rear switch is not pressed.
• On: Power liftgate (PLG) rear switch is pressed.
|
1AF (Power liftgate (PLG) rear switch signal)
|
HAND_SW
|
Off/On
|
• Off: Liftgate opener switch is not pressed.
• On: Liftgate opener switch is pressed.
|
1Z (Liftgate opener switch signal)
|
HL_SW
|
Off/On
|
• Off: Half latch switch is off.
• On: Half latch switch is on.
|
1Q (Half latch switch)
|
IG_STATUS
|
Off/On
|
• Off: Ignition is switched to ACC or OFF.
• On: Ignition is switched ON (engine off or on).
|
1AD (Power supply)
|
I-Stop_ENGST
|
Ready/Cranking/Running/IS_Cond/IS_Stopping/IS_Stoped/IS_Restart/IS_Restarting/IS_Running
|
• Ready: Ignition is switched ON (engine off). (Other than i-stop control)
• Cranking: Engine is cranking.
• Running: Ignition is switched ON (engine on).
• IS_Cond: Verifying if conditions for entering i-stop control are met.
• IS_Stopping: Engine speed is reduced for entering i-stop control.
• IS_Stoped: Engine is stopped. (i-stop control)
• IS_Restart: Verifying if conditions for restarting engine are met.
• IS_Restarting: Engine restarting is completed and engine speed is increased.
• IS_Running: Engine restart after i-stop control is completed and ignition is switched ON (engine on).
|
• 1A (CAN_L)
• 1B (CAN_H)
|
LL_SW_D
|
Lock/Unlock
|
• Lock: Front door lock-link switch (LH) is in lock.
• Unlock: Front door lock-link switch (LH) is in unlock.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
LL_SW_D_LK
|
Off/On
|
• Off: Front door lock-link switch (LH) is in unlock.
• On: Front door lock-link switch (LH) is in lock.
|
1U (Door lock (driver-side))
|
LL_SW_D_UNL
|
Off/On
|
• Off: Front door lock-link switch (LH) is in lock.
• On: Front door lock-link switch (LH) is in unlock.
|
1V (Door unlock (driver-side))
|
LL_SW_P
|
Lock/Unlock
|
• Lock: Front door lock-link switch (RH) is in lock.
• Unlock: Front door lock-link switch (RH) is in unlock.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
LL_SW_P_UNL
|
Off/On
|
• Off: Front door lock-link switch (RH), rear door lock-link switch (LH), rear door lock-link switch (RH) is in unlock.
• On: Front door lock-link switch (RH), rear door lock-link switch (LH), rear door lock-link switch (RH) is in lock.
|
1X (Door unlock (passenger-side and rear))
|
M_CL_CV_L
|
Off/On
|
• Off: Power liftgate (PLG) drive unit motor (LH) close is not operating.
• On: Power liftgate (PLG) drive unit motor (LH) close is operating.
|
• 2A (Liftgate open signal)
• 2C (Liftgate close signal)
|
M_CL_CV_R
|
Off/On
|
• Off: Power liftgate (PLG) drive unit motor (RH) close is not operating.
• On: Power liftgate (PLG) drive unit motor (RH) close is operating.
|
• 2B (Liftgate close signal)
• 2E (Liftgate open signal)
|
M_CL_L
|
V
|
Displays the voltage during a close operation of the power liftgate (PLG) drive unit motor (LH).
|
—
|
M_CL_R
|
V
|
Displays the voltage during a close operation of the power liftgate (PLG) drive unit motor (RH).
|
—
|
M_CNT_L
|
—
|
Displays the power liftgate (PLG) drive unit motor (LH) speed.
|
• 1H (Hall effect switch No.1)
• 1J (Hall effect switch No.2)
|
M_CNT_R
|
—
|
Displays the power liftgate (PLG) drive unit motor (RH) speed.
|
• 1G (Hall effect switch No.1)
• 1I (Hall effect switch No.2)
|
M_OP_CV_L
|
Off/On
|
• Off: Power liftgate (PLG) drive unit motor (LH) open is not operating.
• On: Power liftgate (PLG) drive unit motor (LH) open is operating.
|
• 2A (Liftgate open signal)
• 2C (Liftgate close signal)
|
M_OP_CV_R
|
Off/On
|
• Off: Power liftgate (PLG) drive unit motor (RH) close is not operating.
• On: Power liftgate (PLG) drive unit motor (RH) close is operating.
|
• 2B (Liftgate close signal)
• 2E (Liftgate open signal)
|
M_OP_L
|
V
|
Displays the voltage during a close operation of the power liftgate (PLG) drive unit motor (LH).
|
—
|
M_OP_R
|
V
|
Displays the voltage during a close operation of the power liftgate (PLG) drive unit motor (RH).
|
—
|
M_SEN_A_L
|
Low/High
|
• Low: Hall effect switch 2 (LH) pulse position is at LOW.
• High: Hall effect switch 2 (LH) pulse position is at HI
|
1J (Hall effect switch No.2)
|
M_SEN_A_R
|
Low/High
|
• Low: Hall effect switch 2 (RH) pulse position is at LOW.
• High: Hall effect switch 2 (RH) pulse position is at HI
|
1I (Hall effect switch No.2)
|
M_SEN_B_L
|
Low/High
|
• Low: Hall effect switch 1 (LH) pulse position is at LOW.
• High: Hall effect switch 1 (LH) pulse position is at HI
|
1H (Hall effect switch No.1)
|
M_SEN_B_R
|
Low/High
|
• Low: Hall effect switch 1 (RH) pulse position is at LOW.
• High: Hall effect switch 1 (RH) pulse position is at HI
|
1G (Hall effect switch No.1)
|
NTR_SW_STAT*1
|
Unknown/not Neutral/Neutral/Invalid
|
• Unknown: Neutral switch on/off is not determined.
• not Neutral: Neutral switch is off.
• Neutral: Neutral switch is on.
• Invalid: Neutral switch signal has error.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
PB_STAT
|
Off/ON/Reserved/Unknown
|
• Off: Electric parking brake switch is pressed.
• ON: Electric parking brake switch is pulled up.
• Reserved: —
• Unknown: Electric parking brake switch signal is not determined.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
PC_STAT
|
IG OFF/ACC/IG ON/CRANK
|
• IG OFF: Ignition is switched to OFF.
• ACC: Ignition is switched to ACC.
• IG ON: Ignition is switched ON (engine off or on).
• CRANK: During engine cranking.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
PLG_KEY
|
Off/Open
|
• Off: Power liftgate button of the remote transmitter is not pressed.
• Open: Power liftgate button of the remote transmitter is pressed.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
PLG_M_L
|
A
|
Displays the current during power liftgate (PLG) drive unit motor (LH) operation.
|
• 2A (Liftgate open signal)
• 2C (Liftgate close signal)
|
PLG_M_R
|
A
|
Displays the current during power liftgate (PLG) drive unit motor (RH) operation.
|
• 2B (Liftgate close signal)
• 2E (Liftgate open signal)
|
PLG_SW_D
|
Off/On
|
• Off: Power liftgate (PLG) front switch is not pressed.
• On: Power liftgate (PLG) front switch is pressed.
|
1Y (Power liftgate (PLG) front switch signal (Input))
|
PLG_TRNS_OP
|
Off/Open
|
• Off: Open signal is not received from remote transmitter. (Power liftgate button of the remote transmitter is not pressed.)
• Open: Open signal is received from remote transmitter. (Power liftgate button of the remote transmitter is pressed.)
|
• 1A (CAN_L)
• 1B (CAN_H)
|
PLG_TRNS_SP
|
Off/Stop
|
• Off: Stop signal is not received from remote transmitter. (Power liftgate button of the remote transmitter is not pressed.)
• Stop: Stop signal is received from remote transmitter. (Power liftgate button of the remote transmitter is pressed.)
|
• 1A (CAN_L)
• 1B (CAN_H)
|
RET_SW
|
Off/On
|
• Off: Return switch is off.
• On: Return switch is on.
|
1T (Motor return signal)
|
SHIFT
|
P/R/N/D/S(2)/L(1)
|
Selector lever position signal from PCM
• P: Selector lever is in P position.
• R: Selector lever is in R position.
• N: Selector lever is in N position.
• D: Selector lever is in D position.
• S(2): Selector lever is in D position 2nd gear.
• L(1): Selector lever is in D position 1st gear.
|
• 1A (CAN_L)
• 1B (CAN_H)
|
T_SEN_L
|
V
|
Displays voltage at the power liftgate (PLG) touch sensor (LH)
|
1N (Power liftgate (PLG) touch sensor signal (LH))
|
T_SEN_R
|
V
|
Displays voltage at the power liftgate (PLG) touch sensor (RH)
|
1P (Power liftgate (PLG) touch sensor signal (RH))
|
VPWR_B
|
V
|
Displays voltage at the power supply
|
• 1AA (Power supply)
• 2I (Power supply)
|
VSS
|
KPH, MPH
|
Displays the vehicle speed signal from the PCM.
|
• 1A (CAN_L)