ACTIVE COMMAND MODES TABLE [START STOP UNIT]
id0902p6027600
Simulation item |
Unit/Operation |
Data contents |
Data read/use method |
Output part name |
Operation condition |
---|---|---|---|---|---|
BZR_OUT
|
Off/On
|
• Off: Keyless beeper does not sound.
• On: Keyless beeper sounds.
|
• When the simulation item BZR_OUT is turned on, a force override signal is sent to the LF control unit from the start stop unit, and the LF control unit drives (sounds) the keyless beeper.
• With adoption of a separate excitation buzzer to the keyless beeper, buzzer does not sound normally even if the voltage is applied to the buzzer unit because there is no oscillation circuit. The integrity of the keyless beeper is determined using the simulation item BZR_OUT.
• If the keyless buzzer does not sound even though the simulation function BZR_OUT is on, perform diagnosis using the following procedure.
|
Keyless beeper
|
Ignition switched ON (engine off or on)
|
T_SEN_P_LF
|
Off/On
|
|
|||
T_SEN_P_RF
|
Off/On
|
|