PID/DATA MONITOR TABLE [360°VIEW MONITOR CONTROL MODULE]
id1502c7056800
PID |
Unit/Operation |
Data contents |
Module control terminal |
---|---|---|---|
CAM_BACK
|
NORMAL/Fail
|
• NORMAL:Image signal received from rear mount camera is normal.
• Fail:Normal image signal from rear mount camera cannot be received.
|
U, V, X, W
|
CAM_FRONT
|
NORMAL/Fail
|
• NORMAL:Image signal received from front camera is normal.
• Fail:Normal image signal from front camera cannot be received.
|
Q, R, S, T
|
CAM_LEFT
|
NORMAL/Fail
|
• NORMAL:Image signal received from side camera (LH) is normal.
• Fail:Normal image signal from side camera (LH) cannot be received.
|
Y, Z, AA, AB
|
CAM_RIGHT
|
NORMAL/Fail
|
• NORMAL:Image signal received from side camera (RH) is normal.
• Fail:Normal image signal from side camera (RH) cannot be received.
|
M, N, O, P
|
VMC_SW
|
Off/On
|
• Off:360°view monitor switch is not pressed.
• On:360°view monitor switch is pressed.
|
AE, AF
|
VPWR
|
V
|
Displays the power supply voltage.
|
A
|
VPWR_ST
|
NORMAL/Fail
|
• NORMAL:Power supply status to camera is normal.
• Fail:Power supply status to camera is not normal.
|
M, Q, U, Y
|