DTC C101F:98 [DSC HU/CM]


id040262847100

DTC
C101F:98
Overheat protection control
DETECTION CONDITION
•  Pump motor, traction control solenoid valve and stability control solenoid valve is forcibly operated for 30 s or more is detected.
•  Inlet solenoid valve is forcibly operated for 120 s or more and outlet solenoid valve is forcibly operated for 30 s or more is detected.
FAIL-SAFE FUNCTION
•  Refer to “Fail-safe function table”. (See DTC TABLE [DSC HU/CM].)
POSSIBLE CAUSE
•  Overheating protection control is performed to protect solenoid valve inside DSC HU/CM, however, this is not a malfunction
SYSTEM WIRING DIAGRAM
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY DSC HU/CM DTC
•  Using the M-MDS, clear the DTC from the DSC HU/CM.
•  Using the M-MDS, perform the DSC HU/CM DTC inspection.
•  Is the same DTC present?
Yes
Replace the DSC HU/CM, then go to the next step.
No
Go to the next step.
2
VERIFY NO DTC IS PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.