DTC U2300:54 [POWER LIFTGATE (PLG) CONTROL MODULE]


id0902o8082200

Description

Configuration data not received from instrument cluster

Detection condition
•  The power liftgate (PLG) control module cannot receive configuration data from the instrument cluster with the ignition switched ON (engine off or on).
Fail-safe
•  Stops the power liftgate (PLG) system operation.
Possible cause
Note
•  To correctly write the configuration data sent from the instrument cluster to the power liftgate (PLG) control module to the power liftgate (PLG) control module, 30 s or more need to have elapsed since the ignition was switched ON (engine off or on).
•  DTCs are stored in the instrument cluster.
?  Instrument cluster configuration not implemented
?  Instrument cluster internal memory malfunction
•  Instrument cluster configuration data error
•  Power liftgate (PLG) control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY IF OTHER DTCs DISPLAYED FOR POWER LIFTGATE (PLG) CONTROL MODULE
•  Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
•  Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
•  Is DTC U3000:49 displayed?
Yes
Replace the power liftgate (PLG) control module, then go to step 4.
No
Go to the next step.
2
VERIFY INSTRUMENT CLUSTER DTCs
•  Retrieve the instrument cluster DTCs using the M-MDS.
•  Is the DTC displayed?
Yes
Repair the malfunctioning part according to the applicable DTC troubleshooting.
No
Go to the next step.
3
RESET INSTRUMENT CLUSTER CONFIGURATION DATA
•  Using the M-MDS, perform the instrument cluster configuration with the As-Built data.
•  Clear the power liftgate (PLG) control module DTCs using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 30 s or more.
•  Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.
No
Go to Step 5.
4
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Clear the power liftgate (PLG) control module DTCs using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 30 s or more.
•  Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Replace the power liftgate (PLG) control module, then go to the next step.
No
Go to the next step.
5
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.