DTC U2300:55 [MAZDA ERA-GLONASS CONTROL MODULE]


id0902r6083200

Description

Configuration error (no configuration)

Detection condition
•  Mazda ERA-GLONASS control module detected any of the following conditions with the ignition switched to ON (engine off or on).
?  Mazda ERA-GLONASS control module cannot receive the same configuration data from the instrument cluster twice in a row
?  Mazda ERA-GLONASS control module cannot receive the same configuration data from the PCM twice in a row
?  Configuration data cannot be written to Mazda ERA-GLONASS control module memory.
Fail-safe
•  In factory mode: The mode cannot be switched from factory mode to market mode because test mode cannot be activated.
Test mode is not activated
Possible cause
•  Instrument cluster configuration is not completed.
•  PCM configuration is not completed.
•  Mazda ERA-GLONASS control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY OTHER MAZDA ERA-GLONASS CONTROL MODULE DTCs
•  Clear the DTC for the Mazda ERA-GLONASS control module using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 25 s or more.
•  Perform the DTC inspection for the Mazda ERA-GLONASS control module using the M-MDS.
•  Is DTC U3000:00 displayed?
Yes
Replace the Mazda ERA-GLONASS control module, then go to the Step 4.
No
Go to the next step.
2
VERIFY INSTRUMENT CLUSTER DTCs
•  Retrieve the instrument cluster DTCs using the M-MDS.
•  Are any DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
Go to the next step.
3
RESET CONFIGURATION DATA FROM INSTRUMENT CLUSTER AND PCM TO MAZDA ERA-GLONASS CONTROL MODULE
•  Using the M-MDS, perform the instrument cluster configuration (using As-Built data).
•  Using the M-MDS, perform the PCM configuration (using As-Built data).
•  Clear the DTC for the Mazda ERA-GLONASS control module using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 25 s or more.
•  Perform the DTC inspection for the Mazda ERA-GLONASS control module using the M-MDS.
•  Is the same DTC displayed?
Yes
Using the M-MDS, perform the instrument cluster and PCM configuration (using As-Built data) again, then go to the next step.
No
Go to Step 5.
4
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Clear the DTC for the Mazda ERA-GLONASS control module using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 25 s or more.
•  Perform the DTC inspection for the Mazda ERA-GLONASS control module using the M-MDS.
•  Is the same DTC displayed?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the Mazda ERA-GLONASS control module.
Go to the next step.
No
Go to the next step.
5
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair the malfunctioning location according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.