FOOT-MOTION DETECTION UNIT INSPECTION


id091100809200

1.  Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Remove the foot-motion detection unit. (SeeFOOT-MOTION DETECTION UNIT REMOVAL/INSTALLATION.)

3.  Reconnect the foot-motion detection unit connectors.

4.  Connect the negative battery terminal.

5.  Verify that the voltages of each of the terminals are as indicated in the Terminal Voltage Table (Reference).

•  If the voltage is not as indicated in the table, inspect the parts under Inspection item(s).
?  If the system does not launch normally even though inspection items are normal, specify the location of the malfunction based on the instructions from the on-board diagnostic system and the symptom troubleshooting, and perform repairs.


Terminal Voltage Table (Reference)

ac9uuw00010969

Terminal
Signal
Connected to
Measurement conditions
Voltage (V)
Inspection item(s)
1A
GND
Body ground
Under any condition
1.0 or less
Related wiring harness
1B
+B
25A fuse
Under any condition
B+
•  25A fuse
•  Related wiring harness
1C
SIGNAL
Power liftgate (PLG) control module
Terminal used for communication therefore determination based on terminal voltage is not possible.
2A
SIGNAL
Foot-motion detection sensor up
Terminal used for communication therefore determination based on terminal voltage is not possible.
2B
SIGNAL
Foot-motion detection sensor up
Terminal used for communication therefore determination based on terminal voltage is not possible.
3A
SIGNAL
Foot-motion detection sensor lwr
Terminal used for communication therefore determination based on terminal voltage is not possible.
3B
SIGNAL
Foot-motion detection sensor lwr
Terminal used for communication therefore determination based on terminal voltage is not possible.