WALK-IN ACTUATOR INSPECTION


id091300961300


L.H.D

1.  Disconnect the negative battery terminal and wait for 1 min or more. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Disconnect the walk-in actuator connector.

3.  Apply battery positive voltage and connect the ground to the walk-in actuator terminals as indicated in the table below and verify the operation condition..

LH

ac9wzw00005830

RH

ac9uuw00011019
•  If not as specified, replace the second-row seat. (See SECOND-ROW SEAT REMOVAL/INSTALLATION.)


R.H.D

1.  Disconnect the negative battery terminal and wait for 1 min or more. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Disconnect the walk-in actuator connector.

3.  Apply battery positive voltage and connect the ground to the walk-in actuator terminals as indicated in the table below and verify the operation condition..

LH

ac9uuw00011019

RH

ac9wzw00005830
•  If not as specified, replace the second-row seat. (See SECOND-ROW SEAT REMOVAL/INSTALLATION.)