CAPACITOR (i-ELOOP) RECHARGING [i-ELOOP]
id131704008100
Capacitor Quick Charge
1. Connect the M-MDS to the DLC-2.
2. Turn the capacitor quick charge function on using the M-MDS simulation function (simulation item: CHARGE_FLG). (See ACTIVE COMMAND MODES INSPECTION [i-ELOOP].)
3. Verify the following displays.
4. Switch the ignition OFF (LOCK).
5. Switch the ignition ON (engine off).
6. Wait until the display verified in procedure 3. disappears.
7. Turn the capacitor quick charge function (PID: CHARGE_FLG) off using the M-MDS simulation function. (See ACTIVE COMMAND MODES INSPECTION [i-ELOOP].)
8. Verify that the i-ELOOP operates normally. (See i-ELOOP Operation Verification.)
i-ELOOP Operation Verification
1. Start the engine. (no electrical load)