DTC TABLE [i-ELOOP]


id130201000700

Note
•  When each warning/indicator light turns on/flashes, a message may be displayed in the LCD.

×: Applicable
—: Not applicable

DTC No.

i-ELOOP indicator light (green)*2

i-ELOOP warning light (amber)*2

i-stop warning light (amber)

Charging system warning light

Master warning light

Condition

Fail-safe function

Drive cycle

Self test type*1

Memory function

Page

P0A12:00
OFF
OFF
Flash
ON*3
ON*3
DC-DC converter (i-ELOOP): low input
×
1
C, D
×
P0C39:00
OFF
OFF
OFF
OFF
ON
Capacitor (i-ELOOP) temperature sensor system: function/circuit malfunction
1
C, D
×
P1628:11
OFF
OFF
OFF
OFF
OFF
DC-DC converter (i-ELOOP) system: power supply voltage low input
1
C, D
×
P1794:00
OFF
OFF
OFF
OFF
ON
Capacitor (i-ELOOP) system: Capacitor capacitance deterioration
×
1
C, D
×
P1794:01
OFF
OFF
OFF
OFF
ON
Capacitor (i-ELOOP) system: Pre-charge-related circuit malfunction
×
1
C, D
×
P1794:07
OFF
OFF
OFF
OFF
ON
Capacitor (i-ELOOP) system: Capacitor interrupt relay malfunction (capacitor interrupt relay stuck closed)
1
C, D
×
P1794:11
OFF
OFF
OFF
OFF
ON
Capacitor (i-ELOOP) system: Capacitor-related circuit malfunction (short to ground)
×
1
C, D
×
P1794:13
OFF
OFF
Flash
OFF
ON
Capacitor (i-ELOOP) system: Capacitor-related circuit malfunction (open circuit)
×
1
C, D
×
P1794:14
OFF
OFF
Flash
OFF
ON
Capacitor (i-ELOOP) system: Capacitor voltage detection circuit malfunction (open circuit or short to ground)
×
1
C, D
×
P1794:1B
OFF
OFF
OFF
OFF
ON
Capacitor (i-ELOOP) system: Capacitor internal resistance deterioration
×
1
C, D
×
P1794:49
OFF
OFF
Flash
ON
OFF
Capacitor (i-ELOOP) system: Capacitor interrupt relay malfunction (generator continuously turned on due to capacitor interrupt relay stuck open)
×
1
C, D
×
U0001:88
OFF
OFF
OFF
ON
OFF
CAN system communication error (HS-CAN)
×
1
C, D
×
U0100:00
OFF
OFF
OFF
ON
OFF
CAN communication: communication error to PCM
×
1
C, D
×
U0151:00
OFF
OFF
OFF
OFF
OFF
CAN communication: communication error to SAS control module
1
C, D
×
U0155:00
OFF
OFF
OFF
OFF
OFF
CAN communication: communication error to instrument cluster
1
C, D
×
U3000:49
OFF
OFF
Flash
ON
ON
DC-DC converter (i-ELOOP) internal malfunction
×
1
C, D
×

*1   :C: CMDTC self test, D: ODDTC self test
*2   :Without multi-information display
*3   :The warning light may be illuminated depending on the condition.