DTC U3000:01 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
id1502b5015700
Description |
Electrical malfunction inside blind spot monitoring (BSM) control module |
---|---|
Detection condition
|
• Blind spot monitoring (BSM) control module is detected an electrical malfunction inside.
|
Fail-safe
|
• Blind spot monitoring (BSM) system is stopped.
|
Possible cause
|
• Blind spot monitoring (BSM) control module malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY IF MALFUNCTIONING LOCATION IS BLIND SPOT MONITORING (BSM) CONTROL MODULE DEPENDING ON REPEATABILITY
• Clear the DTC for the blind spot monitoring (BSM) control module using the M-MDS.
• Retrieve the blind spot monitoring (BSM) control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Replace the blind spot monitoring (BSM) control module, then go to the next step.
|
No
|
Go to the next step.
|
||
2
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|