DTC U3000:01 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]


id1502b5015700

Description

Electrical malfunction inside blind spot monitoring (BSM) control module

Detection condition
•  Blind spot monitoring (BSM) control module is detected an electrical malfunction inside.
Fail-safe
•  Blind spot monitoring (BSM) system is stopped.
Possible cause
•  Blind spot monitoring (BSM) control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY IF MALFUNCTIONING LOCATION IS BLIND SPOT MONITORING (BSM) CONTROL MODULE DEPENDING ON REPEATABILITY
•  Clear the DTC for the blind spot monitoring (BSM) control module using the M-MDS.
•  Retrieve the blind spot monitoring (BSM) control module DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Replace the blind spot monitoring (BSM) control module, then go to the next step.
No
Go to the next step.
2
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.