POSITIVE CRANKCASE VENTILATION (PCV) VALVE INSPECTION [SKYACTIV-G 2.5T]


id0116q4800400


Airflow Inspection

1.  Remove the air cleaner cover and air hose as a single unit. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [SKYACTIV-G 2.5T].)

2.  Disconnect the PCV hose from the intake manifold. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [SKYACTIV-G 2.5T].)

3.  Verify that there is no airflow when pressure is applied to the end of the disconnected PCV hose.

•  If there is airflow, replace the PCV valve and the oil separator as a single unit. (See POSITIVE CRANKCASE VENTILATION (PCV) VALVE REMOVAL/INSTALLATION [SKYACTIV-G 2.5T].)

4.  Verify that there is airflow when vacuum is applied to the end of the disconnected PCV hose.

•  If there is no airflow, replace the PCV valve and the oil separator as a single unit. (See POSITIVE CRANKCASE VENTILATION (PCV) VALVE REMOVAL/INSTALLATION [SKYACTIV-G 2.5T].)