AIR BAG SYSTEM WARNING LIGHT DOES NOT ILLUMINATE [AIR BAG SYSTEM]
id0803a3814300
Description
|
• Air bag system warning light does not illuminate while the air bag system is performing initialization.
|
Possible cause
|
• Air bag system warning light circuit malfunction
• Air bag system warning light (LED) malfunction
• Instrument cluster malfunction
• Communication error between SAS control module and instrument cluster
• SAS control module malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT OTHER WARNING AND INDICATOR LIGHTS CIRCUIT IN INSTRUMENT CLUSTER
• Switch the ignition ON (engine off or on).
• Do other warning and indicator lights illuminate?
|
Yes
|
Go to the next step.
|
No
|
Inspect the instrument cluster power supply system and ground system, then go to Step 3.
|
||
2
|
INSPECT DTCs IN SAS CONTROL MODULE
• Inspect the DTC for the SAS control module on-board diagnostic system.
• Have DTCs been recorded in memory?
|
Yes
|
Perform the applicable DTC inspection, then go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
INSPECT DTCs IN INSTRUMENT CLUSTER
• Inspect the DTC for the instrument cluster on-board diagnostic system.
• Have DTCs been recorded in memory?
|
Yes
|
Perform the applicable DTC inspection, then go to the next step.
|
No
|
Go to the next step.
|
||
4
|
VERIFY WHERE MALFUNCTION IS IN WARNING LIGHTS INDICATION CIRCUIT OR ELSEWHERE
• Turn on all warning lights and indicator lights using the instrument cluster PID WL+IL of simulation function using the M-MDS.
• Do other waning and indicator lights illuminate?
|
Yes
|
Go to the next step.
|
No
|
Replace the instrument cluster.
Then go to the next step.
|
||
5
|
VERIFY THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Switch the ignition off.
• Switch the ignition ON (engine off or on).
• Does the air bag system warning light operate properly?
|
Yes
|
Verify that there are no DTCs in the memory. If there are no DTCs, the troubleshooting is completed.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|