DTC U2100:56 [POWER LIFTGATE (PLG) CONTROL MODULE]
id0902o8049400
Description |
Power liftgate (PLG) control module configuration not completed |
---|---|
Detection condition
|
• Power liftgate (PLG) control module configuration not completed.
|
Fail-safe
|
• Stops the power liftgate (PLG) system operation.
|
Possible cause
|
• Power liftgate (PLG) control module configuration error
• Instrument cluster malfunction
• Power liftgate (PLG) control module malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
VERIFY INSTRUMENT CLUSTER DTCs
• Retrieve the instrument cluster DTCs using the M-MDS.
• Are any DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
Go to the next step.
|
||
2
|
VERIFY IF MALFUNCTIONING LOCATION IS INSTRUMENT CLUSTER DEPENDING ON REPEATABILITY
• Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
• Switch the ignition ON (engine off or on) and wait for 1 s or more.
• Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Replace the instrument cluster, then go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
• Switch the ignition ON (engine off or on) and wait for 1 s or more.
• Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Replace the power liftgate (PLG) control module, then go to the next step.
|
No
|
Go to the next step.
|
||
4
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|