DTC U2100:56 [POWER LIFTGATE (PLG) CONTROL MODULE]


id0902o8049400

Description

Power liftgate (PLG) control module configuration not completed

Detection condition
•  Power liftgate (PLG) control module configuration not completed.
Fail-safe
•  Stops the power liftgate (PLG) system operation.
Possible cause
•  Power liftgate (PLG) control module configuration error
•  Instrument cluster malfunction
•  Power liftgate (PLG) control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
VERIFY INSTRUMENT CLUSTER DTCs
•  Retrieve the instrument cluster DTCs using the M-MDS.
•  Are any DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
Go to the next step.
2
VERIFY IF MALFUNCTIONING LOCATION IS INSTRUMENT CLUSTER DEPENDING ON REPEATABILITY
•  Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 1 s or more.
•  Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Replace the instrument cluster, then go to the next step.
No
Go to the next step.
3
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 1 s or more.
•  Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Replace the power liftgate (PLG) control module, then go to the next step.
No
Go to the next step.
4
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.