DTC U2300:55 [POWER LIFTGATE (PLG) CONTROL MODULE]
id0902o8082300
Description |
Instrument cluster configuration not implemented |
---|---|
Detection condition
|
• The power liftgate (PLG) control module received a signal which indicates the instrument cluster configuration is not performed.
|
Fail-safe
|
• Stops the power liftgate (PLG) system operation.
|
Possible cause
|
• Instrument cluster configuration is not completed.
• Instrument cluster malfunction
• Power liftgate (PLG) control module malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY IF OTHER DTCs DISPLAYED FOR POWER LIFTGATE (PLG) CONTROL MODULE
• Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
• Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
• Is DTC U3000:49 displayed?
|
Yes
|
Replace the power liftgate (PLG) control module, then go to step 4.
|
No
|
Go to the next step.
|
||
2
|
VERIFY ALL SYSTEM DTCs
• Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
• Switch the ignition ON (engine off or on) and wait for 30 s or more.
• Perform a CMDTC self-test using the M-MDS.
• Are there any modules other than the power liftgate (PLG) control module displaying DTC U2300:55?
|
Yes
|
Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.
|
No
|
Go to Step 4.
|
||
3
|
VERIFY ALL SYSTEM DTCs AGAIN
• Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
• Switch the ignition ON (engine off or on) and wait for 30 s or more.
• Perform a CMDTC self-test using the M-MDS.
• Are there any modules other than the power liftgate (PLG) control module displaying DTC U2300:55?
|
Yes
|
Replace the instrument cluster, then go to the next step.
|
No
|
Go to the next step.
|
||
4
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear the DTC for the power liftgate (PLG) control module using the M-MDS.
• Switch the ignition ON (engine off or on) and wait for 30 s or more.
• Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Replace the power liftgate (PLG) control module, then go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|