DTC U0423:00 [360°VIEW MONITOR CONTROL MODULE]


id1502c7055800

Description

Error signal received from instrument cluster

Detection condition
•  The 360°view monitor control module detects a signal error from the instrument cluster for a certain period of time or more.
Fail-safe
•  360°view monitor switch operation is disabled.
Possible cause
•  DTCs are stored in the instrument cluster.
•  Instrument cluster malfunction
•  360°view monitor control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY OTHER 360°VIEW MONITOR CONTROL MODULE DTCs
•  Clear the DTC for the 360°view monitor control module using the M-MDS.
•  Retrieve the 360°view monitor control module DTCs using the M-MDS.
•  Is DTC U3000:41 or U3000:49 displayed?
Yes
Replace the 360°view monitor control module, then go to Step 4.
No
Go to the next step.
2
VERIFY INSTRUMENT CLUSTER DTCs
•  Retrieve the instrument cluster DTCs using the M-MDS.
•  Are any DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
Go to the next step.
3
VERIFY IF MALFUNCTIONING LOCATION IS INSTRUMENT CLUSTER DEPENDING ON REPEATABILITY
•  Clear the DTC for the 360°view monitor control module using the M-MDS.
•  Retrieve the 360°view monitor control module DTCs using the M-MDS.
•  Is the same Pending DTC present?
Yes
Replace the instrument cluster, then go to the next step.
No
Go to Step 5.
4
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Clear the DTC for the 360°view monitor control module using the M-MDS.
•  Retrieve the 360°view monitor control module DTCs using the M-MDS.
•  Is the same Pending DTC present?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the 360°view monitor control module.
Go to the next step.
No
Go to the next step.
5
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.