DTC U3003:17 [MAZDA ERA-GLONASS CONTROL MODULE]


id0902r6083900

Description

Mazda ERA-GLONASS control module power supply voltage high input

Detection condition
•  The Mazda ERA-GLONASS control module power supply voltage of 16 V or more is detected with the ignition switched ON (engine off or on).
Fail-safe
Not applicable
Possible cause
•  DTCs are stored in the PCM.
•  Battery malfunction
•  Generator malfunction
•  Mazda ERA-GLONASS control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY MAZDA ERA-GLONASS CONTROL MODULE DTCs AGAIN
•  Clear the DTC for the Mazda ERA-GLONASS control module using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 25 s or more.
•  Perform the DTC inspection for the Mazda ERA-GLONASS control module using the M-MDS.
•  Is the same DTC displayed?
Yes
Go to the next step.
No
Go to Step 6.
2
VERIFY PCM DTCs
•  Retrieve the PCM DTCs using the M-MDS.
•  Are any DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
Go to the next step.
3
INSPECT BATTERY
•  Inspect the battery.
•  Is the battery normal?
Yes
Go to the next step.
No
Recharge or replace the battery, then go to the next step.
4
INSPECT GENERATOR
•  Is the generator normal?
Yes
Go to the next step.
No
Replace the generator, then go to the next step.
5
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Always reconnect all disconnected connectors.
•  Reconnect the negative battery terminal.
•  Clear the DTC for the Mazda ERA-GLONASS control module using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 25 s or more.
•  Perform the DTC inspection for the Mazda ERA-GLONASS control module using the M-MDS.
•  Is the same DTC displayed?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the Mazda ERA-GLONASS control module.
Go to the next step.
No
Go to the next step.
6
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair the malfunctioning location according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.