DTC U3003:17 [POWER LIFTGATE (PLG) CONTROL MODULE]


id0902o8049700

Description

Power liftgate (PLG) control module power supply voltage high input

Detection condition
•  Power liftgate (PLG) control module detects that the power supply circuit voltage of specification or more.
Fail-safe
•  Stops the power liftgate (PLG) system operation.
Possible cause
•  DTCs are stored in the PCM.
•  Battery malfunction
•  Generator malfunction
•  Power liftgate (PLG) control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
VERIFY PCM DTCs
•  Retrieve the PCM DTCs using the M-MDS.
•  Is the DTC displayed?
Yes
Repair the malfunctioning part according to the applicable DTC troubleshooting.
No
Go to the next step.
2
INSPECT BATTERY
•  Inspect the battery.
•  Is the battery normal?
Yes
Go to the next step.
No
Replace the battery, then go to Step 4.
3
INSPECT GENERATOR
•  Is the generator normal?
Yes
Go to the next step.
No
Replace the generator, then go to the next step.
4
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Clear the power liftgate (PLG) control module DTCs using the M-MDS.
•  Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the power liftgate (PLG) control module, then go to the next step.
No
Go to the next step.
5
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.