DTC U3003:17 [POWER LIFTGATE (PLG) CONTROL MODULE]
id0902o8049700
Description |
Power liftgate (PLG) control module power supply voltage high input |
---|---|
Detection condition
|
• Power liftgate (PLG) control module detects that the power supply circuit voltage of specification or more.
|
Fail-safe
|
• Stops the power liftgate (PLG) system operation.
|
Possible cause
|
• DTCs are stored in the PCM.
• Battery malfunction
• Generator malfunction
• Power liftgate (PLG) control module malfunction
|
System wiring diagram
|
Not applicable
|
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
VERIFY PCM DTCs
• Retrieve the PCM DTCs using the M-MDS.
• Is the DTC displayed?
|
Yes
|
Repair the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
Go to the next step.
|
||
2
|
INSPECT BATTERY
• Inspect the battery.
(See BATTERY INSPECTION.)
• Is the battery normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the battery, then go to Step 4.
(See BATTERY REMOVAL/INSTALLATION.)
|
||
3
|
INSPECT GENERATOR
• Inspect the generator.
• Is the generator normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the generator, then go to the next step.
|
||
4
|
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
• Clear the power liftgate (PLG) control module DTCs using the M-MDS.
• Retrieve the power liftgate (PLG) control module DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the power liftgate (PLG) control module, then go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|