DTC U3003:17 [360°VIEW MONITOR CONTROL MODULE]


id1502c7056600

Description

360°view monitor control module high power supply voltage input

Detection condition
•  The 360°view monitor control module detects that the power supply circuit voltage of the 360°view monitor control module is more than the specified range for a certain period of time.
Fail-safe
•  Black screen displayed when system is starting
Possible cause
•  DTCs are stored in the PCM.
•  Battery malfunction
•  Generator malfunction
•  360°view monitor control module malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY OTHER 360°VIEW MONITOR CONTROL MODULE DTCs
•  Clear the DTC for the 360°view monitor control module using the M-MDS.
•  Retrieve the 360°view monitor control module DTCs using the M-MDS.
•  Is DTC U3000:41 or U3000:49 displayed?
Yes
Replace the 360°view monitor control module, then go to Step 5.
No
Go to the next step.
2
VERIFY PCM DTCs
•  Retrieve the PCM DTCs using the M-MDS.
•  Are any DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
Go to the next step.
3
INSPECT BATTERY
•  Inspect the battery.
•  Is the battery normal?
Yes
Go to the next step.
No
Replace the battery, then go to Step 5.
4
INSPECT GENERATOR
•  Is the generator normal?
Yes
Go to the next step.
No
Replace the generator, then go to the next step.
5
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Clear the DTC for the 360°view monitor control module using the M-MDS.
•  Retrieve the 360°view monitor control module DTCs using the M-MDS.
•  Is the same Pending DTC present?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the 360°view monitor control module.
Go to the next step.
No
Go to the next step.
6
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.