DTC TABLE [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)]


id0702k2801700

Note
•  There are two types of front climate control unit, type A and type B.
ac9wzw00005446

X: Applicable
—: Not applicable

DTC No.

Warning/indicator light

System malfunction location

Fail-safe function

Drive cycle

Self test type*1

Memory function

Page

B1081:71
Driver-side front air mix actuator motor lock (L.H.D.)
Passenger-side front air mix actuator motor lock (R.H.D.)
X
C
X
B1082:71
Passenger-side front air mix actuator motor lock (L.H.D.)
Driver-side front air mix actuator motor lock (R.H.D.)
X
C
X
B1086:71
Front airflow mode actuator motor lock
X
C
X
B10FB:71
Air intake actuator motor lock
X
C
X
B1142:13
Rear climate control unit power supply circuit open (IG1)
C, D
X
B1143:13
Rear climate control unit power supply circuit open (IG2)
C, D
X
B11F0:12
Air intake actuator (potentiometer) circuit short to power supply
X
C, D
X
 
B11F0:13
Air intake actuator (potentiometer) circuit open
X
C, D
X
B11F5:86
Invalid data (temperature) received from humidity sensor
X
C, D
X
B1259:12
Rear airflow mode actuator (potentiometer) circuit short to power supply
X
C, D
X
 
B1259:13
Rear airflow mode actuator (potentiometer) circuit open
X
C, D
X
B1354:71
Rear air mix actuator motor lock
X
C
X
B13AB:12
Rear air mix actuator (potentiometer) circuit short to power supply
X
C, D
X
B13AB:13
Rear air mix actuator (potentiometer) circuit open
X
C, D
X
B1A61:11
Cabin temperature sensor circuit short to ground
X
C, D
X
B1A61:13
Cabin temperature sensor circuit open
X
C, D
X
B1A63:12
Solar radiation sensor (RH) circuit shot to power supply
X
C, D
X
B1A63:13
Solar radiation sensor (RH) circuit open
X
D
X*2/—*3
B1A64:12
Solar radiation sensor (LH) circuit shot to power supply
X
C, D
X
B1A64:13
Solar radiation sensor (LH) circuit open
X
D
X*2/—*3
B1A69:86
Invalid data (humidity) received from humidity sensor
X
C, D
X
B1B71:11
Evaporator temperature sensor circuit short to ground
X
C, D
X
B1B71:13
Evaporator temperature sensor circuit open
X
C, D
X
B1B7D:71
Rear airflow mode actuator motor lock
X
C
X
B1C1A:12
Driver-side front air mix actuator (potentiometer) circuit short to power supply (L.H.D.)
Passenger-side front air mix actuator (potentiometer) circuit short to power supply (R.H.D.)
X
C, D
X
B1C1A:13
Driver-side front air mix actuator (potentiometer) circuit open (L.H.D.)
Passenger-side front air mix actuator (potentiometer) circuit open (R.H.D.)
X
C, D
X
B1C1B:12
Passenger-side front air mix actuator (potentiometer) circuit short to power supply (L.H.D.)
Driver-side front air mix actuator (potentiometer) circuit short to power supply (R.H.D.)
X
C, D
X
B1C1B:13
Passenger-side front air mix actuator (potentiometer) circuit open (L.H.D.)
Driver-side front air mix actuator (potentiometer) circuit open (R.H.D.)
X
C, D
X
B1C1C:12
Front airflow mode actuator (potentiometer) circuit short to power supply
X
C, D
X
B1C1C:13
Front airflow mode actuator (potentiometer) circuit open
X
C, D
X
U0010:88
Unit communication error (MS-CAN)
C
X
U0155:00
Communication error with instrument cluster
X
C, D
X
U0164:00
Communication error with front climate control unit
X
C, D
X
U0165:00
Communication error with rear climate control unit
X
C, D
X
U0423:68
Invalid data received from Instrument cluster
X
C, D
X
U0424:68
Rear climate control unit had invalid data received from front climate control unit
X
C, D
X
U0466:68
Front climate control unit had invalid data received from rear climate control unit
X
C, D
X
U200D:11
Front climate control unit circuit voltage (+5V) circuit short to ground
C, D
X
U200E:12
Rear climate control unit circuit voltage (+5V) circuit short to ground
C, D
X
U2101:54
Rear climate control unit configuration error (data not received)
C, D
X
U2101:55
Rear climate control unit configuration error (not configured)
C, D
U2101:56
Rear climate control unit configuration error (ineffective/non-interchangeable data read)
X
C, D
X
U2101:64
Rear climate control unit configuration error (error value read)
C, D
X
U210A:86
Invalid data (windshield temperature) received from humidity sensor
X
C, D
X
U2300:54
Front climate control unit configuration error (data not received)
C, D
X
U2300:55
Front climate control unit configuration error (not configured)
C, D
U2300:56
Front climate control unit configuration error (ineffective/non-interchangeable data read)
X
C, D
X
U2300:64
Front climate control unit configuration error (error value read)
C, D
X
U3003:16
Front climate control unit power supply circuit voltage below threshold (10.00 V or less)
C, D
X
U3003:17
Front climate control unit power supply circuit voltage above threshold (17.30 V or more)
C, D
X
U3006:16
Rear climate control unit power supply circuit voltage below threshold (10.00 V or less)
C, D
X
U3006:17
Rear climate control unit power supply circuit voltage above threshold (17.30 V or more)
C, D
X
U300E:13
Front climate control unit power supply circuit open (IG1)
C, D
X
U300F:13
Front climate control unit power supply circuit open (IG2)
C, D
X

*1   :C: CMDTC self test, D: ODDTC self test
*2   :Front climate control unit type A
*3   :Front climate control unit type B